Methanol casserole electric furnace intelligent controller

98.75 $

442 in stock

Additional information

Certification

CE / EU

Feature

Stocked

Type

Kitchen Lighters

Origin

Mainland China

Model Number

M1 m2 m3 m1e m5

Material

Plastic

Plastic Type

Melamine

Description

M1 electrification controller

New M1 gasification controller

M1E type with belt rocker switch control

M2 type with flameout protection

M3 controller with control fan

M5 type with flameout protection and fan control

First, M series electric vaporization controller description

System parameter setting method: Press and hold the setting button to enter the system parameter setting, turn the knob to select the desired menu, press the setting button to display the value, turn the knob to adjust the value, and then press and hold the setting button until the SAU is displayed, indicating that the saving is successful. Note: If you do not see SAU, it will not be saved successfully, and the system will still work according to the previous parameters.

Operation instructions: Press the knob to start the operation, ignite and spray the oil. When burning, turn the knob to adjust the firepower. Press the knob to stop the work when burning. At this time, enter the holding standby state and press the knob to enter the OFF state.

Timing fire function operation: During the combustion process, press the timing button to flash “10.”, turn the knob to change the time, 5 seconds to automatically start the countdown without stopping, and the timer will automatically turn off the fire. Press the time button during the countdown process, the number flashes, and turn the knob to change the time. Press the time button twice, the timer light goes out and the timing function is canceled.

Fault code: “HHH” is displayed: the temperature is too high or the thermocouple is open; “LLL” is displayed: the temperature is too low or the polarity of the thermocouple is reversed.

1, dIn menu firepower minimum; default value: 28.8; setting range: 0.0-100; ★ function description: the minimum firepower value that can be achieved by turning the knob.

2, dAn menu is the maximum firepower; default value: 43.8; setting range: 0.0-100; ★ function description: the maximum firepower value that can be achieved by turning the knob.

3, oPP menu is the starting firepower value; default value: 30; setting range: 0.0-100; ★ function description: press the knob to start the firepower value.

4, SP menu is the target temperature value; default value: 190 ° C; setting range: 60-300 ° C; ★ function description: the temperature to be reached by electric heating, to stop heating.

5, Aol menu is the starting temperature value; default value: 130 ° C; setting range: 50-200 ° C; ★ function description: greater than or equal to this temperature can start combustion.

6, HHH menu is the highest protection temperature value; default value: 450 ° C; setting range: 300-500 ° C; ★ function description: stop burning above the maximum protection temperature.

7. The SC menu is the temperature correction value; the default value is 0°C; the setting range is -20-20°C; ★ Function description: The correction value when the temperature is deviated.

8, odH menu is the ignition delay time; default value: 12 seconds; setting range: 3-20 seconds; ★ function description: ignition from the start to the automatic stop time.

9, Str menu is to start the rotation of the virtual position; default value: 1 grid; setting range: 0-20 grid; ★ function description: stop state knob to start the work of the number of grids, 0 is the swing open function off.

10, SoP menu is to stop rotating the virtual position; default value: 1 grid; setting range: 0-20 grid; ★ function description: the minimum fire state knob to stop working the number of grids, 0 is the knob off function.

11, dEl menu is the pump delay value; default value: 2 grid; setting range: 0-20 grids; ★ Function description: Rotate the knob to start the pump grid number after ignition, 0 is the pump starts at the same time.

12, UPo menu is the start heating option; default value: 0 grid; setting range: 0-1 grid; ★ function description: 0: power is not heated; 1: automatic heating after power on.

13. SEPo menu is the knob firepower adjustment speed; default value: 0.3; setting range: 0.1-10; ★ Function description: The smaller the value, the finer and slower the adjustment. The larger the value, the faster the adjustment.

14, LEF menu is low temperature protection option; default value: 1; setting range: 0-1; ★ function description: 0 is no low temperature protection; 1 is low temperature protection.

15, tIE menu is the default timing time; default value: 10 minutes; setting range: 1-999 minutes; ★ function description: press the timer button after the default countdown time, time to automatically turn off the fire.